Description

Differential fuel flowmeter Eurosens Delta
In stock

Differential fuel flowmeter Eurosens Delta

Category: Eurosens

Brand: Eurosens

Differential fuel flowmeter Eurosens Delta is used to measure fuel consumption of diesel engines in supply and return lines.

It measures both flows and calculates the difference precisely right after the installation is done. No calibration needed. 

Eurosens Delta provides more than 20 parameters, including Operating Time and Fuel Temperature.

Flow meter index (100,250,500) means maximum fuel rate in each measuring chamber. It is a main parameter to choose suitable flow meter. Note: engine fuel consumption – it is only part of fuel rate in supply and return fuel flow.

499.00

Advantages

  • Accurate measurement with temperature correction;
  • Corrosion-resistant casing with sealed automobile connector integrated;
  • Strong electronic circuit protection;
  • Magnetic-resistant;
  • Warranty term – 2 years, without fuel flow limitation.
  • Smart software data processing;
  • Deaerator will help to exclude air from the fuel system.

Note: Differential method of fuel consumption measurement requires high-accuracy data from the fuel flowmeter, as usually fuel consumption in supply and return lines significantly exceeds that of an engine.

Fuel flow meters Eurosens Delta are made from hard aluminum alloy. The measuring chambers of Eurosens Delta have anti-friction coating, in both chambers, there is a fuel temperature sensor installed. Delta flowmeters are pre-calibrated for differential application. Thereby Delta flowmeters can provide accurate results in any mode of engine operation.

Specifications

Connecting threadM14x1, 5 (M16x1,5 for 500)
Max pressure2.5 MPa
Power voltage, V10 – 50
Reverse polarity protectionYes
Temperature range,°C-40 – +85
Maximum flow rate in l/h *100/250/500
Output interfacepulses, RS232, RS485, K-Line, CAN
Seal ratingIP 67
  •  
Flow meter modelQ start, liters/hourQ min, liters/hourQ nom, liters/hourQ max, liters/hour  Pulses per literError*
Delta PN 1000,51050100200± 1.2%
Delta PN 2500,520125250100± 1.2%
Delta PN 5001,09025050050± 1.5%
Delta PN 100 I0,51050100200± 1.2%
Delta PN 250 I0,520125250100± 1.2%
Delta PN 500 I1,09025050050± 1.5%
Delta PN A 100 I0,51050100200± 1.2%
Delta PN A 250 I0,520125250100± 1.2%
Delta PN A 500 I1,09025050050± 1.5%
Delta RS 1000,51050100200± 1.2%
Delta RS 2500,520125250100± 1.2%
Delta RS 5001,09025050050± 1.5%
Delta RS 100 I0,51050100200± 1.2%
Delta RS 250 I0,520125250100± 1.2%
Delta RS 500 I1,09025050050± 1.5%
Delta CAN 1000,51050100200± 1.2%
Delta CAN 2500,520125250100± 1.2%
Delta CAN 5001,09025050050± 1.5%
Delta CAN 100 I0,51050100200± 1.2%
Delta CAN 250 I0,520125250100± 1.2%
Delta CAN 500 I1,09025050050± 1.5%

Q start  – flow rate when fuel meter starts to measure Q min , Q max – Min and Max flow rate for range with declared precision РN – Pulse output RS – Serial interfaces RS-232/RS-485 CAN – CAN bus  interface SAE J1939 I – build-in LED display, 9-digit А – built-in long-life battery * Error calculated for fuel supply/consumption values   (Liters/hour)  : serie 100 – 45/10 ; serie 250 – 90/20; serie 500 – 160/30